076200 SHEET METAL FLASHING AND TRIM
Airex Catalog

210548 VIBRATION AND SEISMIC CONTROLS FOR FIRE-SUPPRESSION PIPING AND EQUIPMENT
Airex Catalog

213413 Pressure Maintenance Pumps
Airex Catalog

220548 VIBRATION AND SEISMIC CONTROLS FOR PLUMBING PIPING AND EQUIPMENT
Airex Catalog

220548 VIBRATION AND SEISMIC CONTROLS FOR PLUMBING PIPING AND EQUIPMENT
Airex Catalog

230517 SLEEVES AND SLEEVE SEALS FOR HVAC PIPING
Airex Catalog

230529 HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT
Airex Catalog

230548 VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT
Airex Catalog

230548 VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT
Airex Catalog

230553 IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT
Airex Catalog

230719 HVAC PIPING INSULATION
Airex Catalog

232113 HYDRONIC PIPING
Airex Catalog

  Full Length
077200  ROOF ACCESSORIES
230517  SLEEVES AND SLEEVE SEALS FOR HVAC PIPING
230719  HVAC PIPING INSULATION

Airex Manufacturing Inc. is the leader of the engineered AIREX PRO-SYSTEM KIT™ an all-in-one system for combined air-tight sealing wall-mounted piping outlets and UV/Vapor Retarder insulation protection system for exterior HVAC refrigerant piping penetrations and outdoor insulation located at the point of service connections for outdoor equipment.

AIREX PRO-SYSTEM KIT™ offers improved sustainability, energy efficiency, and optimum performance of building wall, outdoor pipe insulation, and HVAC equipment. Due to the multi-dimensional complexities of recent building energy codes, building codes, green codes, mechanical codes, residential codes, and standards within this category, specifying AIREX PRO-SYSTEM KIT™ is the only guaranteed solution to meet all your needs and mandatory requirements.

Product Offerings
AIREX PRO-SYSTEM KIT
o All-in-one system for combined air-tight sealing wall-mounted piping outlets and UV/Vapor Retarder insulation protection system for exterior HVAC refrigerant piping penetrations and outdoor insulation
AIREX TITAN OUTLET
o Air-tight sealing wall-mounted refrigerant piping outlet
AIREX E-FLEX GUARD
o UV/Vapor Retarder insulation protection for outdoor refrigerant thermal pipe insulation

Use on Applications
Exterior Vertical Walls: Building Walls, Roof Parapet Walls, Roof Curb Walls, and Roof Service Walls
Surfaces: Stucco, Masonry, Siding, Concrete, Metal Paneling, Brick, and Roof Membranes
Thermal insulation on outdoor refrigerant piping

Product Highlights
• Superior aesthetic design using best-in-class engineered materials
• Gasket compression system seals air-leakage and weather moisture
• Protects indoor air quality
• Outdoor UV/Weather grade resistant construction
• Flexible sleeve reduces piping vibration and noise
• Prevents physical wall damage and pest intrusion
• Class II vapor retarder
• Self-gripping, industrial grade dual-bonded, hook & loop molecular-bonded fastening system
• Removable/Reusable for maintenance

Approved Performance & Material Testing
• ASTM E283 – Air Leakage
• ASTM G153 – Weatherization and UV Exposure
• ASTM E331 – Water Penetration
• ASTM E84 – Flame and Smoke
• ASTM E96 – Vapor Permeability
• ASTM E2178 – Air Permeance
• ASTM G21 – Anti-microbial and Anti-fungal
• ASTM D570 – Tensile Strength
• UL 94 HB – Flame Rating
• UL 746C – Outdoor Suitability

CODES & STANDARDS COMPLIANCE
• IBC - 2006, 2009, 2012 Chapter 13
• IRC - 2006, 2009, 2012 Chapter 11 Part IV Energy Efficiency - Section N1101 General - N1101.1 Scope - Air Leakage Section N1102.4 Section N1102.4.1 - Building Thermal Envelope - (1. All joints, seams, penetrations)
• Chapter 11 Refrigeration Section 1101.0 Scope -1101.3 Protection
• IECC - 2006, 2009, & 2012 Air Leakage (Mandatory) - Residential Section 402.4.1 and 402.4.1.1 Building Thermal Envelope – Penetrations
• IECC - 2006, 2009, & 2012 Air Leakage (Mandatory) - Commercial Section C502.4.3 and C402.4.2 Building Thermal Envelope – Penetrations
• IMC - 2006, 2009, & 2012 Chapter 3 General Regulations Section 301.1 Scope – Sections 301.10, 301.11, 301.14, 301.15, 305.1, 305.2, 305.4
• UMC - 2006, 2009, & 2012 Chapter 11 Refrigeration – Section 1101.0 Scope - Section 1101.1 - General Requirements Section 1106.0 – Section 1106.2, Section 1111.0 Erection of Refrigerant Piping – Sections 1111.1, 1111.2, 1111.4
• California Building Energy Efficiency Standards (TITLE 24 ENERGY CODE) 2013 Air Leakage (Mandatory) - All Occupancies Section 117 Joints and other Openings/Exterior Wall Penetrations
• IECC 2012 - Protection of Piping Insulation – Commercial Section C403.2.8.1
• IECC 2015 - Protection of Piping Insulation – Commercial Section C403.2.10.1
• IRC 2018 – Refrigerant Line Insulation Protection – M1411.6.1 - Section N1103.4.1
• 2013 California Title 24 (Energy Efficiency Standards) - Residential & Commercial Requirement for Pipe Insulation120.3 – Section: 150.0(j) 3a & b
• 2016 California Title 24 (Energy Efficiency Standards) - Residential & Commercial Requirement for Pipe Insulation120.3 – Section: 150.0(j) 2 & 3 – Section 150.0(m) 9
• ANSI/ASHRAE/IESNA Standard 90.1 - 2004, 2007, 2010

Online Resource Offerings
• Mechanical Detail Drawings
• 3 Part Specification
• BIM Files
• Engineer CAD Library